本試劑盒用于測定人血清、血漿及相關(guān)液體樣本中GPX)含量。
實驗原理
本試劑盒應(yīng)用雙抗體夾心法測定標(biāo)本中人白介素GPX水平。用純化的人GPX抗體包被微孔板,制成固相抗體,往包被單抗的微孔中依次加入白介素GPX再與HRP標(biāo)記的白介素GPX抗體結(jié)合,形成抗體-抗原-酶標(biāo)抗體復(fù)合物,經(jīng)過*洗滌后加底物TMB顯色。TMB在HRP酶的催化下轉(zhuǎn)化成藍(lán)色,并在酸的作用下轉(zhuǎn)化成zui終的黃色。顏色的深淺和樣品中的白介素GPX呈正相關(guān)。用酶標(biāo)儀在450nm波長下測定吸光度(OD值),通過標(biāo)準(zhǔn)曲線計算樣品中人白介素GPX)濃度。
如需了解人谷胱甘肽過氧化物酶ELISA試劑盒價格是否有折扣、*或是否有調(diào)整,請咨詢我司業(yè)務(wù)人員:,.
Human glutathione peroxidase (GPX)
FOR RESEARCH USE ONLY
Assay range:10ng/L -260ng/L 96 determinations Purpose
This kit allows for the determination of GPX concentrations in Human serum, cell culture supernates and other biological fluids
Principle of the assay
The kit assay Human GPX level in the sample,use Purified Human GPX antibody to coat microtiter plate wells, make solid-phase antibody, then add GPX to wells, Combined GPX antibody which With HRP labeled,become antibody - antigen - enzyme-antibody complex, after washing Compley, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of Human GPX in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Materials provided with the kit
1 | wash solution | 20ml× 1bottle | 7 | Stopp Solution | 6ml× 1 bottle | 2 | HRP-Conjugate reagent | 6ml× 1 bottle | 8 | Standard(480ng/L) | 0.5ml× 1 bottle | 3 | Microelisa stripplate | 12well× 8strips | 9 | Standard diluent | 1.5ml× 1bottle | 4 | Sample diluent | 6ml× 1 bottle | 10 | Instruction | 1 | 5 | Chromogen Solution A | 6ml× 1 bottle | 11 | Closure plate membrane | 2 | 6 | Chromogen Solution B | 6ml× 1 bottle | 12 | Sealed bags | 1 | |
Specimen requirements
1. extract as soon as possible after Specimen collection,and according to the relevant
literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20 ℃ to preserve, Avoid repeated freeze-thaw cycles.
2. Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.
Assay procedure
1. Dilute and add sample:Dilute Original density Standard as follow table:
2.add sample:Set blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.
240ng/L | 5 Standard | 150μl Original density Standard+150μl Standard diluent | 120ng/L | 4 Standard | 150μl 5 Standard+150μl Standard diluent | 60ng/L | 3 Standard | 150μl 4 Standard+150μl Standard diluent | 30ng/L | 2 Standard | 150μl 3 Standard +150μl Standard diluent | 15ng/L | 1 Standard | 150μl 2 Standard +150μl Standard diluent | |
3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37℃. 4.Configurate liquid: 30-fold(or 20-fold) wash solution diluted 30-fold (or 20-fold) with distilled water and reserve.
5.washing:Uncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.
6.add enzyme:Add HRP-Conjugate reagent 50μl to each well, except blank well.
7.incubate:Operation with 3.
8.washing:Operation with 5.
9.color:Add Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37℃
1 the reaction:Add Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).
2 take blank well as zero , Read absorbance at 450nm after Adding Stop Solution and
within 15min.
Steps description
Standard, Sample diluent
Add Standard, Sample diluent, incubate for 30 min at 37℃.
Wash 5 time,Add HRP-Conjugate reagent, incubate for 30 min at 37℃.
Wash 5 times,Add Chromogen Solution A and B, incubate for 30 min at 37℃.
Add Stopp Solution
Read absorbance at 450nm within 15 min
calculate
Calculate
Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor, the result is the sample actual density.
Important notes
1. The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.
2. washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.
3. add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .
4. if the testing material content is excessively higher (The sample OD is bigger than the first
standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.(× n× 5).
5. Closure plate membrane only limits the disposable use, to avoid cross-contamination.
6. The substrate evade the light preservation.
7. Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.
8. All samples, washing buffer and each kind of reject should according to infective material process.
9. Do not mix reagents with those from other lots.
Storage and validity
1.Storage: 2-8℃.
2.validity: six months